Double-walled stainless steel modular duct with sealing gasket and 30 mm high density rock wool intermediate insulation

EI30VENT with seal

Specific range for industrial kitchens. High quality and performance

Double-walled stainless steel modular duct with sealing gasket and 30 mm high density rock wool intermediate insulation


Product specifically designed and certified for the extraction of industrial cooker hoods (P > 20 kW), including the mandatory registration and cleaning elements according to CTE

FIRE RESISTANCE CLASSIFICATION: EI 30/30 ve-ho (i↔o)

The EI30VENT range range has been tested in accordance with the EN 1366-1 certification for ventilation ducts, and classified as “fire-resistant” according to EN 13501-3

EI 30 ve (i↔o)
EI 30 ho (i↔o)

Benefits

EI 30 Certification

It has all the certifications required by the CTE in this type of applications, being certified EI 30 in interior and exterior fire conditions, both for vertical assemblies, EI 30 ve (i↔o), and horizontal assemblies, EI 30 ho (i↔o)

Inspection and cleaning

The inspection and cleaning registers have been specifically designed for this application, and have been tested and certified together with the duct, in accordance with the requirements of the CTE

Resistance and robustness

The design of the parts gives them high stability and mechanical resistance, also guaranteeing a reduced thermal bridge

Assembly

Double-walled stainless steel modular duct with sealing gasket and 30 mm high density rock wool intermediate insulation

Technical features

Generic

Guaranteed minimum EI fire resistance of 30 min.

Overlap between elements:

20 mm from Ø125/185 to 600/660 mm.

40 mm from Ø650/710 to 1.000/1.060 mm

Silicone seal on the joints between elements to guarantee watertightness

Safety-End finish on the ends of all parts for greater safety and mechanical resistance

Materials and thicknesses

Inner wall:

Stainless steel AISI 304 BA (1.4301) or AISI 316L BA (1.4404)

Thickness:

0.4 mm from Ø125/185 to 600/660 mm

0.6 mm from Ø650/710 to 1,000/1,060 mm


Outer wall:

Stainless steel AISI 304 BA (1.4301) or AISI 316L BA (1.4404)

Thickness:

0,4 mm from Ø125/185 to 300/360 mm

0,5 mm from Ø350/410 to 600/660 mm

0.6 mm from Ø650/710 to 1,000/1,060 mm

Stainless steel AISI 409 BA (1.4512). Please check with Dinak for availability

Thickness:

0.4 mm from Ø125/185 to 300/360 mm

0.6 mm from Ø350/410 to 600/660 mm

Galvanised steel (only for internal mounting)

Thickness:

0,4 mm from Ø125/185 to 300/360 mm

0.5 mm from Ø350/410 to 600/660 mm

Copper

Thickness:

0.5 mm from Ø125/185 to 300/360 mm

Optional painted (R.A.L. range)


Insulation:

High-density rock wool insulation 30 mm thick

Temperature classes

Up to 200ºC (T200)

Sealing classes

Sealing class N1

Up to 300 Pa overpressure

Up to 500 Pa suction (negative pressure)

Diameters

125/185

150/210

175/235

200/260

225/285

250/310

300/360

350/410

400/460

450/510

500/560

550/610

600/660

650/710

700/760

750/810

800/860

850/910

900/960

950/1010

1000/1060

Certifications

Products

Módulo recto 020 EI30 Junta
Straight Lengths

Downloads

Do you want more information about EI30VENT with seal?

Contact us

You may also be interested in